Calibration procedures and uncertainty analysis for a thermal mass gas flowmeter of a new generation
Affiliation:1. Second University of Naples, Italy;2. University of Naples Federico II, Italy;3. INRIM, TURIN, Italy;1. Izmir University of Economics, Faculty of Engineering and Computer Science, Balcova, Izmir, Turkey;2. University of Missouri-Columbia, College of Engineering, Columbia, MO, USA;1. Department of Design and Manufacturing Engineering, Universidad de Zaragoza, Zaragoza, Spain;2. Centro Universitario de la Defensa, Zaragoza, Spain;1. Universidade Estadual de Campinas – UNICAMP, Faculdade de Engenharia Química – FEQ, Campinas, SP, Brazil;2. Industria Eletromecânica Balestro Ltda., Mogi Mirim, SP, Brazil;3. Universidade de São Paulo – USP, Escola Politécnica, Depto. de Engenharia de Energia e Automação Elétricas – PEA, São Paulo, SP, Brazil;4. Universidade Estadual de Campinas – UNICAMP, Faculdade de Engenharia Elétrica e de Computação – FEEC, Campinas, SP, Brazil;5. Centro de Pesquisas de Energia Elétrica – CEPEL, Rio de Janeiro, RJ, Brazil
Abstract:This paper deals with the differences between traditional and new technology gas meters, and focuses specifically on the calibration procedure and uncertainty evaluation of CTTMFs (Capillary Type Thermal Mass Flow Meter). In particular, measurements performed on a sample set of commercial CTTMFs for natural gas in domestic/residential (G4) applications allowed to evaluate the modifications to calibration procedures required by the new generation, digital, gas flow meters. Indeed, traditionally natural gas is metered by means of volumetric measurement techniques, while the modern, static gas flow meters (thermal and ultrasonic ones) are based on electronic flow sensors. This implies that the gas volume through the meter is measured by sampling the flow rate at selected time points and integrating the flow rate in time. The measurement time becomes therefore an important parameter, thus requiring a thorough rethinking of the calibration procedure. In order to analyse the effects of the various parameters, a series of ad-hoc calibrations were performed. Specifically, one set of calibrations was performed with constant totalized volume, while the other required a constant measurement time. In order to highlight the novelties that will have to be implemented in ordinary calibration procedures to get the best of the new technologies, the two procedures as performed on a sample set CTTMFs will be compared; the theoretical (generic) evaluation of the associated uncertainty will also be presented. Measurements were carried out at the test facility of INRIM, the Italian National Metrology Institute.
Keywords:Smart gas meter  Calibration  Flowmeter
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号