摘    要:采用电感耦合等离子体原子发射光谱-标准加入法(ICP-AES-标准加入法)探讨铝合金中痕量钠的测定.以盐酸、过氧化氢溶解试料,优化全谱型ICP-AES分析条件,标准加入法测定铝合金中痕量钠,检出限为0.028 μg/mL(588.995 nm).用该方法测定铝合金中0.00014%~0.00073%钠含量,加标回收率在92%~110%之间,连续测定5个结果的相对标准偏差小于0.25%.

关 键 词:ICP-AES  标准加入法  铝合金  痕量钠

Determination of Trace Sodium Content In Aluminium Alloy by ICP-AES
YU Jin,LI Qi-hua,FAN Chao-ying,MA Ying. Determination of Trace Sodium Content In Aluminium Alloy by ICP-AES[J]. Sichuan Metallurgy, 2013, 0(6): 53-56
Authors:YU Jin  LI Qi-hua  FAN Chao-ying  MA Ying
Affiliation:(Physical and Chemical Test Center of Ordnance Industry in The South - West Area of China,Chongqing 410020,China)
Abstract:A method was studied for the determination of trace sodium content in aluminum alloy by ICP - AES. By using hydrochloric acid and hydrogen peroxide 30% to dissolve samples, trace sodium content in the aluminum alloy were determined according to the optimum condition of ICP - AES. the detection limit were 0. 028 μg/mL(588. 995nm). The results of trace sodium content were between 0. 00014% - 0. 00073%. The relative standard deviations of five samples was less than 0. 25%.