首页 | 本学科首页   官方微博 | 高级检索  
     

过渡金属二硫化物拉曼散射在免疫检测中的应用
引用本文:楚学影,沙雪,徐铭泽,李金华,金芳军.过渡金属二硫化物拉曼散射在免疫检测中的应用[J].光学精密工程,2018,26(3):572-577.
作者姓名:楚学影  沙雪  徐铭泽  李金华  金芳军
作者单位:长春理工大学 理学院 吉林 长春 130022
基金项目:国家自然科学基金资助项目(No.61205193);吉林省科技发展计划资助项目(No.20140520107JH,No.20140204025GX)
摘    要:为了利用可见光激发下半导体拉曼散射信号实现生物检测,以窄带隙的MoS_2材料构建了拉曼免疫标记探针,用于实现对人IgG分子的高特异性识别。首先,运用液相剥离法分别获得了MoS_2和WS_2微米材料,以加热陈化处理分析了温度对532nm激发下样品拉曼散射信号强度的影响。之后借助3-巯基丙酸修饰向MoS_2材料表面引入羧基,进而获得了可用于免疫检测的拉曼探针。最后,以"抗体-待测物-抗体"的三层结构分析了基于MoS_2拉曼散射的免疫检测性能。实验发现适当温度下加热陈化处理可增强过渡金属二硫化物的拉曼散射强度(70℃下最优)。多组对照实验结果表明,免疫检测生物芯片的拉曼信号强度随人IgG浓度的升高而升高,最终趋于饱和,最低浓度的检测限达到1fM,实现了可见光激发下利用半导体拉曼散射信号对目标分子的高灵敏度、高特异性免疫检测。

关 键 词:生物检测  过渡金属二硫化物  拉曼散射  温度  免疫球蛋白
收稿时间:2017-07-10

Application of Raman scattering properties of transition metal dichalcogenides in immunoassays
CHU Xue-ying,SHA Xue,XU Ming-ze,LI Jin-hua,JIN Fang-jun.Application of Raman scattering properties of transition metal dichalcogenides in immunoassays[J].Optics and Precision Engineering,2018,26(3):572-577.
Authors:CHU Xue-ying  SHA Xue  XU Ming-ze  LI Jin-hua  JIN Fang-jun
Affiliation:School of Science, Changchun University of Science and Technology, Changchun 130022, China
Abstract:To realize biodetection based on Raman scattering of semiconductor under visible light excitation, the Raman probe was constructed by using MoS2 material, a narrow bandgap semiconductor, to realize high specific recognition of the human IgG molecule. First, MoS2 and WS2 micromaterials were obtained by liquid-phase exfoliation method. The effect of temperature on the intensity of the Raman signal excitated by a 532 nm laser was analyzed through heating and aging treatment. Second, the carboxyl group was introduced to the surface of the MoS2 material by 3-mercaptopropionic acid modification, and a Raman probe was obtained. Finally, the performance of the MoS2 based immunoassay was evaluated by using a sandwich structure of "antibody-analyte-antibody". It was found that the heating and aging treatment at appropriate temperature enhanced the Raman scattering intensity of the transition metal disulfide (70℃ is the optimal). The results of control groups show that the Raman intensity of the immunodetection increased and saturated with the concentration of the human IgG. The detection limit is 1 fM. The current procedure realized immunoassays with high sensitivity and high specificity by using the Raman scattering of semiconductor under visible light excitation.
Keywords:bioinstrumentation  transition metal dichalcogenides  Raman scattering  temperature  immunoglobulin
本文献已被 CNKI 等数据库收录!
点击此处可从《光学精密工程》浏览原始摘要信息
点击此处可从《光学精密工程》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号