首页 | 本学科首页   官方微博 | 高级检索  
     

一种在线同时分析一氧化氮和二氧化氮含量的方法
引用本文:朱新强,白松春.一种在线同时分析一氧化氮和二氧化氮含量的方法[J].光学仪器,2018,40(2):11-17.
作者姓名:朱新强  白松春
作者单位:上海舜宇恒平科学仪器有限公司
摘    要:氮氧化物(NO_x)在工业生产和科学研究中具有重要的应用。通过多通道快速质谱碎片扣除的方法来测定气体中氮氧化物的含量,旨在实现在线多通道同时快速准确分析一氧化氮(NO)和二氧化氮(NO_2)。方法的稳定性较好,一氧化氮和二氧化氮的稳定性相对标准偏差分别小于1.07%和1.23%。该方法具有快速分析的特点,30s内完成流路切换、进样和样气平衡到检测报告样气组分的全部过程。该方法已分别用于单通道和多通道切换检测氮氧化物含量,所得结果准确。结果表明,多通道质谱干扰离子扣除法可以成功地应用于气体中NO_x含量的快速多点动态监测。

关 键 词:多通道快速质谱  在线定量分析  氮氧化物
收稿时间:2018/3/5 0:00:00

On-line simultaneous analysis of nitric oxide and nitrogen dioxide
ZHU Xinqiang and BAI Songchun.On-line simultaneous analysis of nitric oxide and nitrogen dioxide[J].Optical Instruments,2018,40(2):11-17.
Authors:ZHU Xinqiang and BAI Songchun
Affiliation:Shanghai Sunny Hengping Scientific Instrument Co., Ltd., Shanghai 200233, China and Shanghai Sunny Hengping Scientific Instrument Co., Ltd., Shanghai 200233, China
Abstract:Nitrogen oxides(NOx) plays a very important role in the industrial applications and scientific research.To meet the requirements of multi-channel on-line analysis of nitric oxide and nitrogen dioxide simultaneously,a fast analysis method based on fragment ion subtraction with on-line mass spectrometry for determination of nitrogen oxides in gases was evaluated.The relative standard deviation of the stablility was less than 1.07% for nitric oxide and 1.23% for nitrogen dioxide,respectively.The analysis including stream switching,sample introduction and settling time can be finished within 30 seconds per sample.The developed method was validated for the analysis of NOx based on a single and multi-channel sampling system.The results confirmed that this rapid,feasible,multi-point dynamic monitoring technique can be suitable for the analysis of NOx in gases in the various areas.
Keywords:multi-channel fast mass spectrometry  on-line quantitative analysis  nitrogen oxides