Variation characteristics of aquifer parameters induced by groundwater source heat pump operation under variable flow |
| |
Authors: | WANG Song-qing ZHANG Xu College of Mechanical Engineering Tongji University Shanghai China |
| |
Affiliation: | WANG Song-qing,ZHANG Xu College of Mechanical Engineering,Tongji University,Shanghai 200092,China |
| |
Abstract: | The variation characteristics of aquifer parameters,induced by groundwater source heat pump(GWSHP) operation under variable flow,were theoretically analyzed through a case study,in which the characteristics of building air conditioning load were considered.The results,compared with the constant flow operation,indicate that the influence on the variations of porosity,hydraulic conductivity and confined water head is decreased by 48%,51% and 71%,respectively,under variable flow operation.The security of varia... |
| |
Keywords: | groundwater source heat pump variation characteristic aquifer parameter variable flow |
本文献已被 CNKI 维普 SpringerLink 等数据库收录! |
|