35000m~3/h空分设备粗氩塔氮塞的原因及处理
引用本文:何玉君. 35000m~3/h空分设备粗氩塔氮塞的原因及处理[J]. 深冷技术, 2006, 0(2): 52-54
作者姓名:何玉君
作者单位:鞍钢新钢铁公司氧气厂,辽宁省,鞍山市,114021
摘    要:简介了鞍钢引进的35000m3/h内压缩流程空分设备的流程和性能参数,详细分析了粗氩塔发生氮塞的原因,阐述了为消除氮塞而采取的措施。

关 键 词:大型空分设备  内压缩流程  粗氩塔  氮塞
文章编号:1009-9425(2006)02-0052-03
收稿时间:2005-10-13
修稿时间:2005-10-13

Analysis and treatment of nitrogen block in raw argon column of 35000 m3/h air separation unit
He Yu-jun. Analysis and treatment of nitrogen block in raw argon column of 35000 m3/h air separation unit[J]. Cryogenic Technology, 2006, 0(2): 52-54
Authors:He Yu-jun
Affiliation:Oxygen Factory, New Iron and Steel Company of Anshan Iron and Steel Group Corporation, Anshan 114021, Liaoning , P. R. China
Abstract:The flow and specifications of a 35000 m~3/h air separation unit with internal compression flow have been introduced.After detailed cause analysis of nitrogen block in raw argon column,the measures for eliminating the fault have been described.
Keywords:Large scale separation unit  Internal compression flow  Raw argon column  Nitrogen block