首页 | 本学科首页   官方微博 | 高级检索  
     


Results of Complex Tests of the TGMP-314 Boiler of Cogeneration Plant-23 of the Mosénergo Company After Renovation
Authors:Yu P Enyakin  N A Zroichikov  B N Glusker  I V Galas  Yu M Tsypkin  V Z Zaretskii  B P Enyakin  B N Nosov  V V Chuprov  S N Anichkov  V A Vereshchatin
Affiliation:(1) All-Russia Thermal Engineering Institute (VTI), Russia.;(2) Mosénergo Cogeneration Plant-23, Russia.;(3) ORGRÉS, Russia.;(4) Russia.
Abstract:Results of complex tests of the TGMP-314 boiler of thermal power plant-23 of the Mosénergo Company operating on natural gas and furnace oil after design improvement are presented. Toxic emissions of nitrogen oxides were diminished by the use of low-toxicity burners, supply of air to secondary blow nozzles, and introduction of recirculating gases into the burner channels. These measures lowered the emissions of NOx, benz(a)pyrene, and other harmful substances into the atmosphere below the standardized values. The boiler proved to operate reliably in the entire range of tested loads in the gas- and oil-fired modes with stage firing and recirculation of flue gases. The rated parameters of live steam and reheat steam were steadily maintained.
Keywords:nitrogen oxides  benz(a)pyrene  natural gas  oil fuel  low-toxicity burners  recirculation  two-stage firing  reliability of operation
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏