The vibration performance experiment of Tuned Liquid damper and Tuned Liquid Column damper
Authors:Young-Moon Kim  Ki-Pyo You  Ji-Eun Cho  Dong-Pyo Hong
Affiliation:1. Department of Architecture and Urban Engineering, Chonbuk National University, 561-756, Chonju, Korea
2. Department of Precision Mechanical Engineering, Chonbuk National University, 561-756, Chonju, Korea
Abstract:Tuned Liquid damper and Tuned Liquid Column are kind of passive mechanical damper which relies on the sloshing of liquid in a rigid tank for suppressing structural vibrations. TLD and TLCD are attributable to several potential advantages —low costs; easy to install in existing structures; effective even for small-amplitude vibrations. In this paper, the shaking table experiments were conducted to investigate the characteristics of water sloshing motion in TLD (rectangular, circular) and TLCD. The parameter obtained from the experiments were wave height, base shear force and energy dissipation. The shaking table experiments show that the liquid sloshing relies on amplitude of shaking table and frequency of tank. The TLCD was more effective control vibration than TLD.