引用本文:吴梅青,周国娥.循环流化床锅炉热效率查定及达标达产技术改造[J].化工文摘,2011(11):19-21.
作者姓名:吴梅青  周国娥
作者单位:[1]湘潭职业技术学院,湖南湘潭411102 [2]湖南化工职业技术学院,湖南株洲412004
摘    要:某大型药厂75t/h循环流化床锅炉自从竣工投产后,热效率一直较低,并且装置一直不能达标达产。通过对锅炉进行热效率查定,找到原因,并针对所发现的问题制定对应的技改方案。改造完后,进行达标达产验收连续测试,取得了较满意的效果。

关 键 词:循环流化床锅炉  热效率  达标达产  技术改造  验收测试

CFB Boiler Thermal Efficiency Assessment and Technical Improvement of attaining the Production Goals
Authors:WU Mei-qing  ZHOU Guo-e
Affiliation:1.Xiangtan Vocational and Technical College,Xiangtan 411102,China;2.Hunan Chemical Vocational Technical College,Zhuzhou 412004,China)
Abstract:The thermal efficiency of a large pharmaceutical 75t / h CFB boiler is low and the device could not meet the production goal since production.After assess thermal efficiency,the reason is found.Technical improvement is implemented according to the problems found.After the improvement,the continuous testing shows that the device obtains satisfactory results.