An internal cusp reflector for an evacuated tubular heat pipe solar thermal collector
Authors:U Ortabasi  WM Buehl
Affiliation:Corning Glass Works, Research and Development Laboratory, Corning, NY 14830, U.S.A.
Abstract:This study involves the optical analysis of a slightly concentrating, symmetric cusp reflector inside a tubular glass envelope with a cylindrical heat pipe as the solar absorber. The basic design features of this non-tracking, evacuated, modular collector and the principles of heat removal are shown in Figs. 1 and 2. Differential equations of the cusp reflector optics, given the geometrical restrictions in Figs. 1 and 2, are derived, and solutions for the largest possible aperture inside a given diameter envelope and acceptance angle are presented.As an extension of the same study, the optical efficiency of a single collector tube has been simulated by means of a Monte Carlo Ray-Tracing Program. For a concentration ratio of 1.15, the flux distribution around the heat pipe is computed as a function of incidence angle. In addition, the impact of mirror defects and absorber misalignment on the optical performance are analyzed.
Keywords:
本文献已被 ScienceDirect 等数据库收录!