首页 | 本学科首页   官方微博 | 高级检索  
     


Effect of vacuum plasma surface treatment on the titanium alloy resistance to static and cyclic loading
Authors:A. P. Gopkalo  A. V. Rutkovskii  V. I. Mirnenko
Affiliation:(1) Pisarenko Institute of Problems of Strength, National Academy of Sciences of Ukraine, Kiev, Ukraine;(2) National Academy of Defence of Ukraine, Kiev, Ukraine
Abstract:We present the results of the experimental investigations on the static and cyclic strength of titanium alloy VT20 with a TiN vacuum plasma coating. This coating has been found to increase the static strength characteristics and to reduce the plasticity characteristics. Under conditions of low-cycle loading, the coating application results in the improvement in the cyclic strength characteristics in quasistatic fracture and in their deterioration in fatigue fracture. __________ Translated from Problemy Prochnosti, No. 1, pp. 100–106, January–February, 2007.
Keywords:stresses  strain  fracture  cyclic loading  low-cycle fatigue  cyclic life