750波导引起测频偏差原因分析及解决方案
引用本文:段国文.750波导引起测频偏差原因分析及解决方案[J].舰船电子对抗,2009,32(2):53-55.
作者姓名:段国文
作者单位:海军驻成都电子设备军事代表室,成都,610036
摘    要:在某侦察设备中使用750波导引起宽带瞬时测频接收机测频误差偏大。分析了产生原因,并提出两种解决方案:延长测频接收机的采样时间;采用截止频率更低的650波导。

关 键 词:测频误差  波导  谐波  瞬时测频

Reason Analysis and Solution Method of Frequency Measurement Error Caused by 750 Wave-guide
DUAN GUO-wen.Reason Analysis and Solution Method of Frequency Measurement Error Caused by 750 Wave-guide[J].Shipboard Electronic Countermeasure,2009,32(2):53-55.
Authors:DUAN GUO-wen
Affiliation:Electronics Equipments Military Representative Office of Navy at Chengdu;Chengdu 610036;China
Abstract:Using 750 wave-guide in a certain reconnaissance equipment causes the frequency measurement error over the index in the instantaneous frequency measurement receiver.This paper analyzes the reason causing the error,and presents two solution methods:delays the sampling time of the frequency measurement receiver;adopts 650 wave-guide with lower cut-off frequency.
Keywords:frequency measurement error  wave-guide  harmonic  instantaneous frequency measurement  