摘    要:对双法兰差压变送器在线检测流体密度的检测原理进行了探讨,提供了一些现场应用的实践经验,供设计和使用者参考。

关 键 词:双法兰差压变送器  密度测量  原理与依据  工程应用  问题与方法

Design and Practice of Double Flanges Differential Pressure Transmitter Which is Used for Measuring Fluid Density
Wu Shenglin. Qilu Petrochemical Corp.No. Chemical Fertilizer Plant,Zibo. Design and Practice of Double Flanges Differential Pressure Transmitter Which is Used for Measuring Fluid Density[J]. Automation in Petro-chemical Industry, 1998, 0(5): 5-8
Authors:Wu Shenglin. Qilu Petrochemical Corp.No. Chemical Fertilizer Plant  Zibo
Affiliation:Wu Shenglin. Qilu Petrochemical Corp.No.2 Chemical Fertilizer Plant,Zibo,255400
Abstract:The measurement principle of the differential pressure transmitter used for measuring fluid density on line is studied.The practice experience on site is introduced as reference for design and application.
Keywords:Double flanges differential pressure transmitter  Density measurement  Principle and bases  Engineering application  Problem and method