首页 | 本学科首页   官方微博 | 高级检索  
     

铸钢冷却壁对炉内操作的影响
引用本文:李传辉,张国营.铸钢冷却壁对炉内操作的影响[J].山东冶金,2002,24(Z1):79-81.
作者姓名:李传辉  张国营
作者单位:济南钢铁集团总公司,技术中心,山东,济南,250101
摘    要:济钢 4#高炉中修集中安装三段 (84块 )铸钢冷却壁后 ,因铸钢冷却壁冷却强度大 ,易造成炉墙结厚 ,通过采用控制合适的水流量及水温差、相应的装料制度、热制度、送风制度及上下调剂的操作制度 ,达到了高炉高效顺行又长寿的目的

关 键 词:高炉  铸钢冷却壁  炉墙结厚  操作制度
修稿时间:2002年4月18日

Effect of Cast Steel Cooling Stave on Furnace Operation
LI Chuan hui,ZHANG Guo ying.Effect of Cast Steel Cooling Stave on Furnace Operation[J].Shandong Metallurgy,2002,24(Z1):79-81.
Authors:LI Chuan hui  ZHANG Guo ying
Abstract:Three parts (84 pieces) of cast steel cooling staves are installed centrally during the intermediate relining of No.4 BF at Jigang, then the effect of cast steel stave on furnace operation is analyzed. It is pointed out that the cast steel cooling stave's great cooling intensity results in BF wall accretion easily. Through controlling the appropriate water flow and water temperature difference, the related charging system, thermal system, blast system and operation system of top and bottom adjusting, the BF can get high efficiency, smooth operation and long campaign.
Keywords:blast furnace  cast steel cooling stave  wall accretion  operation system
本文献已被 CNKI 万方数据 等数据库收录!