Critical and Subcritical Mass Calculations of Curium-243 to -247 Based on JENDL-3.2 for Revision of ANSI/ANS-8.15
Abstract:Critical and subcritical masses were calculated for a sphere of five curium isotopes from 243Cm to 247Cm in metal and in metal-water mixtures considering three reflector conditions: bare, with a water reflector or a stainless steel reflector. The calculation were made mainly with a combination of a continuous energy Monte Carlo neutron transport calculation code, MCNP, and the Japanese Evaluated Nuclear Data Library, JENDL-3.2. Other evaluated nuclear data files, ENDF/B-VI and JEF-2.2, were also applied to find differences in calculation results of the neutron multiplication factor originated from different nuclear data files. A large dependence on the evaluated nuclear data files was found in the calculation results: more than 10%Δk/k relative differences in the neutron multiplication factor for a homogeneous mixture of 243Cm metal and water when JENDL-3.2 was replaced with ENDF/B-VI and JEF-2.2, respectively; and a 44% reduction in the critical mass by changing from JENDL-3.2 to ENDF/B-VI for 246Cm metal. The present study supplied basic information to the ANSI/ANS-8.15 Working Group for revision of the standard for nuclear criticality control of special actinide elements. The new or revised values of the subcritical mass limits for curium isotopes accepted by the ANSI/ANS-8.15 Working Group were finally summarized.
Keywords:critical mass  subcritical mass  curium 243  curium 244  curium 245  curium 246  curium 247  bare  water  SS-304  JENDL-3.2  MCNP  ANSI/ANS-8.15  revision