Abstract:This study is concerned with the experimental investigation into the seismic behaviour and retrofitting of gravity-load-designed reinforced-concrete (RC) shear wall structures in Singapore. These structures are designed according to the British Standard (BS8110 1985 BS8110. 1985. Structural use of concrete parts 1, 2 and 3, London: British Standards Institution.  Google Scholar]). For this purpose, 1/5 scaled models (with and without retrofitting), representing the lower critical regions of a 25-story RC shear wall structure, were tested under cyclic loadings. Test results showed that the shear wall failed at the base due to shear and that the pushover test provides a simplified representation of the cyclic test. Retrofitting the wall with GFRP (glass fibre reinforced polymer) system resulted in improved performances of up to 20% to 30% higher ultimate load capacity and displacement. The study provides an insight into the seismic behaviour of such structures and the mechanism of the proposed retrofitting scheme for improving the structural resistance to seismic loads.
Keywords:seismic behaviour  structural retrofitting  shear wall structures  gravity load design  fibre reinforced polymer  cyclic loads