摘    要:研制一种用于农药残留现场快速检测的微流控芯片。设计制作的一次性高聚物微流控芯片集成进样、酶抑制反应、显色反应及检测单元,结合自制的手持式光度分析检测装置,可以实现对有机磷、氨基甲酸酯类农药的现场、低成本、快速、准确的检测。结果表明:通过在芯片内部固定存储生化试剂,只需一次进样,7 min内即可实现对克百威和乐果的快速检测,最低检出限分别为0.02、0.6 mg/L,对克百威加标回收率为95.0%~103.3%,制作的芯片在1 个月内的稳定性较好。使用微流控农药残留快速检测芯片系统,有望实现全自动检测流程,特别适合于基层非专业人员开展现场、快速、高通量的农药残留筛查。

关 键 词:微流控芯片  农药残留  快速检测  低成本  

Fabrication and Analytical Application of Microfludic Chip for Rapid On-Site Detection of Pesticide Residues
YUAN Baolong,WANG Xiaodong,YANG Ping,FANG Zhenzhen,HUANG Yujun,CHEN Jiong,YE Jiaming.Fabrication and Analytical Application of Microfludic Chip for Rapid On-Site Detection of Pesticide Residues[J].Food Science,2016,37(2):198-203.
Authors:YUAN Baolong  WANG Xiaodong  YANG Ping  FANG Zhenzhen  HUANG Yujun  CHEN Jiong  YE Jiaming
Affiliation:1. Department of Biology and Marine Science, School of Marine Science, Ningbo University, Ningbo 315211, China; 2. Yangtze Delta Region Institute of Tsinghua University, Jiaxing 314006, China; 3. China National Center for Food Safety Risk Assessment Cooperation Center for Application Technology, Jiaxing 314006, China
Abstract:A novel disposable microfludic chip was developed for rapid detection of pesticide residues in agricultural
products, which integrated sampling, enzyme inhibition reaction, color development and detection chamber. By coupling
with a laboratory-prepared colorimetric detection device, the chip could provide a simple, easy to use, low-cost and sensitive
approach for rapid detection of organophosphate and carbamate pesticides on site. Due to pre-storage of biochemical
reagents in the chip, the detection could be achieved within 7 min by just one injection. The limits of detection (LOD) of
the method were 0.02 mg/L for carbofuran and 0.6 mg/L for dimethoate, the recoveries of carbofuran from spiked samples
were in the range of 95.0% to 103.3%. Furthermore, this microfludic chip had a long storage life of up to 30 days. The
microfluidic chip coupled with laboratory-prepared detection device is expected to achieve an automatic detection process,
and is particularly suitable for on-site, rapid, and high-throughput screening of pesticide residues by non-professionals.
Keywords:microfludic chip  pesticide residues  rapid detection  low cost  
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《食品科学》浏览原始摘要信息
点击此处可从《食品科学》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号