10岁中国儿童参考人面元体模的建立
引用本文:胡安康,邱睿,代明亮,马锐垚,武祯,李春艳,张辉,李君利,闫淯淳,袁新宇. 10岁中国儿童参考人面元体模的建立[J]. 原子能科学技术, 2019, 53(1): 187-192. DOI: 10.7538/yzk.2018.youxian.0161
作者姓名:胡安康  邱睿  代明亮  马锐垚  武祯  李春艳  张辉  李君利  闫淯淳  袁新宇
作者单位:1.清华大学 工程物理系,北京100084;2.清华大学 粒子技术与辐射成像教育部重点实验室,北京100084;3.同方威视技术股份有限公司,北京100084;4.首都儿科研究所附属儿童医院 放射科,北京100020
摘    要:本文基于首都儿科研究所提供的中国儿童真实CT扫描图像建立了10岁中国儿童参考人面元体模。采用了多边形网格模型与NURBS曲面模型相结合的方法,建立了10岁中国儿童的多边形网格面元。体模包括85个器官,经过优化和调整,各组织和器官质量与GBZ/T 200 2-2007和亚洲参考人的参考值差异小于1%,各器官位置和形态符合中国儿童解剖学特征。该面元体模为10岁中国儿童剂量的准确计算提供了重要工具。

关 键 词:10岁儿童体模   面元体模   中国参考人   CT扫描

Development of 10-year-old Chinese Pediatric Reference Boundary Representation Phantom
HU Ankang,QIU Rui,DAI Mingliang,MA Ruiyao,WU Zhen,LI Chunyan,ZHANG Hui,LI Junli,YAN Yuchun,YUAN Xinyu. Development of 10-year-old Chinese Pediatric Reference Boundary Representation Phantom[J]. Atomic Energy Science and Technology, 2019, 53(1): 187-192. DOI: 10.7538/yzk.2018.youxian.0161
Authors:HU Ankang  QIU Rui  DAI Mingliang  MA Ruiyao  WU Zhen  LI Chunyan  ZHANG Hui  LI Junli  YAN Yuchun  YUAN Xinyu
Affiliation:1.Department of Engineering Physics, Tsinghua University, Beijing 100084, China;2.Key Laboratory of Particle & Radiation Imaging, Ministry of Education, Tsinghua University, Beijing 100084, China; 3.Nuctech Company Limited, Beijing 100084, China;4.Department of Radiology, Capital Institute of Pediatrics, Beijing 100020, China
Abstract:10-year-old Chinese pediatric reference boundary representation phantom based on CT images of Chinese children was developed in this paper. The mesh-type phantom using both polygon-mesh and NURBS surfaces was established. The phantom was divided into 85 organs. The mass of individual organ was adjusted to the GBZ/T 200 2—2007 and Asian reference man with the difference less than 1% after the optimization of organs. The shape and position of all organs are consistent with the anatomical characteristics of Chinese children. This phantom provides an effective tool to estimate the dose of 10-year-old Chinese children accurately.
Keywords:10-year-old pediatric phantom  boundary representation phantom  Chinese reference man  computed tomography scan