首页 | 本学科首页   官方微博 | 高级检索  
     

液氧泵进液管堵塞原因分析及处理
引用本文:黄昌华,胡连桃,徐立珍,孔华. 液氧泵进液管堵塞原因分析及处理[J]. 深冷技术, 2006, 0(2): 55-56
作者姓名:黄昌华  胡连桃  徐立珍  孔华
作者单位:徐州空军学院三系,江苏省,徐州市中山北路西阁街85号,221006
摘    要:介绍了KL-15型制氧制氮车液氧泵进液管被堵塞的现象,分析了产生的原因,并提出了解决问题的方法。

关 键 词:小型空分设备  移动式  液氧泵  管路  堵塞
文章编号:1009-9425(2006)02-0055-02
收稿时间:2005-06-06
修稿时间:2005-08-27

Cause analysis and treatment of block at liquid inlet tube in liquid oxygen pump
Huang Chang-hua,Hu Lian-tao,Xu Li-zhen,Kong Hua. Cause analysis and treatment of block at liquid inlet tube in liquid oxygen pump[J]. Cryogenic Technology, 2006, 0(2): 55-56
Authors:Huang Chang-hua  Hu Lian-tao  Xu Li-zhen  Kong Hua
Affiliation:The Third Department, Xuzhou Air Force College, 85 Xige Street, Zhongshanbei Road, Xuzhou 221006, Jiangsu , P. R. China
Abstract:The phenomenon of block at liquid inlet tube in liquid oxygen pump of KL-15 type oxygen-and nitrogen-producing vehicle has been described.Solutions for the malfunction are also proposed,based on cause analysis.
Keywords:Small scale air separation unit  Mobile type  Liquid oxygen pump  Pipeline  Block
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号