首页 | 本学科首页   官方微博 | 高级检索  
     


Effect of fiber type and content on bleeding of steel fiber reinforced concrete
Authors:Tayfun Uygunoğlu
Affiliation:Afyon Kocatepe University, Technical Education Faculty, Construction Department, 03200 Afyonkarahisar, Turkey;Department of Materials Engineering, Université Paris-Est, French Public Works Research Laboratory (LCPC) Paris, France;Department of Structural Engineering , Université Paris-Est, French Public Works Research Laboratory (LCPC)Paris, France
Abstract:In general, the addition of fibers in concrete mix significantly improves many of the engineering properties of concrete. On the other hand, steel fibers reduce the workability of concrete. This paper presents the effect of steel-fiber length (aspect ratio) and content on bleeding of steel fiber reinforced concrete (SFRC). Two different steel fiber types (both is hooked-end) were used at a ratio of 0% (control), 0.3%, 0.64%, 1% and 1.3% by volume. Slump, Ve-Be test, air content and unit weight were determined experimentally. Specimens were poured in the standard moulds and the bleeding water content was measured 30 min, 60 min, 90 min, 120 min, 150 min and 180 min after starting the test. The results indicated that the workability of concrete significantly reduced as the fiber dosage rate increases. This was assessed through standard slump test and Ve-Be consistometer test. The bleeding water content was increased by increase of the fiber volume fraction and fiber aspect ratio according to experimental results. Also, a bleeding coefficient value for SFRC made with and without steel fiber was proposed as a result of this study.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏