天荒坪抽水蓄能电站2号机组抬机原因分析
引用本文:乐振春,孔令华.天荒坪抽水蓄能电站2号机组抬机原因分析[J].水电站机电技术,2005,28(5):11-13.
作者姓名:乐振春  孔令华
作者单位:华东天荒坪抽水蓄能有限责任公司,浙江安吉313302
摘    要:2003年1月2号机组发电增加负荷过程中(200→300MW)发生转动部分抬起事故,上迷宫环内梳齿严重磨损。对抬机原因进行了分析。针对预防蓄能机组抬机提出了建议。希望能为蓄能电站设计、调试和运行提供参考。

关 键 词:抽水蓄能  机组  抬起  水推力测量

Cause analysis on rotating part lifting of Unit 2 in Tianhuangping Pumped Storage Plant
Authors:LE Zhen-chun  KONG Ling-hua
Abstract:Rotating part lifted up while loading 200 MW up to 300 MW for Unit 2 of Tianhuangping Pumped Storage Plant. Thus the inner finges of the upper labyrinth ring were damaged. This paper describes the process of the lifting, check and test of Unit 2, analyzes the cause of the accidental lift. Furthermore, some suggestions about design, debugging and operation of pumped storage units are given in order to prevent the accidental lift.
Keywords:pumped storage units  lifting  water thrust force  cause analysis  preventative suggestion