首页 | 本学科首页   官方微博 | 高级检索  
     


Arsenic removal from geothermal waters with zero-valent iron--effect of temperature, phosphate and nitrate
Authors:Tyruvola Konstantina  Nikolaidis Nikolaus P  Veranis Nikolaus  Kallithrakas-Kontos Nikolaso  Koulouridakis Pavlos E
Affiliation:Department of Environmental Engineering, Technical University of Crete, 73100 Chania, Crete, Greece.
Abstract:Field column studies and laboratory batch experiments were conducted in order to assess the performance of zero-valent iron in removing arsenic from geothermal waters in agricultural regions where phosphates and nitrates were present. A field pilot study demonstrated that iron filings could remove arsenic, phosphate and nitrate from water. In addition, batch studies were performed to evaluate the effect of temperature, phosphate and nitrate on As(III) and As(V) removal rates. All batch experiments were conducted at three temperatures (20, 30 and 40 degrees C). Pseudo-first-order reaction rate constants were calculated for As(III), As(V), phosphate, nitrate and ammonia for all temperatures. As(V) exhibited greater removal rates than As(III). The presence of phosphate and nitrate decreased the rates of arsenic removal. The temperature of the water played a dominant role on the kinetics of arsenic, phosphate and nitrate removal. Nitrate reduction resulted in the formation of nitrite and ammonia. In addition, the activation energy, Eact, and the constant temperature coefficient, theta were determined for each removal process.
Keywords:Geothermal   Zero-valent iron   Arsenic   Phosphate   Nitrate
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号