摘    要:分光计的调整相对繁琐,其中最关键的一步就是如何调整分光计的中心轴和望远镜的光轴垂直。现提出了如何巧妙地应用干涉仪对分光计的载物台装置进行水平调节,并给出了快速、精确调整望远镜光轴和分光计中心轴垂直的方法。使用该方法在很大程度上缩短了调节时间并且提高了测量的准确性。

关 键 词:分光计  光轴  干涉仪

The application about interferometer in spectrometer adjustment
WEN Jing,ZUO Chunying. The application about interferometer in spectrometer adjustment[J]. Optical Instruments, 2008, 30(4): 32-35
Authors:WEN Jing  ZUO Chunying
Abstract:Spectrometer′s adjustment is relatively tedious,the most essential step is how to adjust spectrometer′s central shaft and telescope′s optical axis vertical.How to apply the interferometer to carry on the adjustment ingeniously to spectrometer′s objective table installment level has been proposed,and the adjustment method with which how to adjust fleetly and accurately telescope optical axis and the spectrometer central shaft vertical has been given in the paper.The survey accuracy is enhanced and accommodation time is reduced to a great extent using this method.
Keywords:spectrometer  light axis  interferometer