首页 | 本学科首页   官方微博 | 高级检索  
     

90K低温下带预冷的林德制冷机的系统设计
引用本文:汤长征,时阳,王生软.90K低温下带预冷的林德制冷机的系统设计[J].低温工程,2008(1):38-40.
作者姓名:汤长征  时阳  王生软
作者单位:郑州轻工业学院机电工程学院,郑州,450002
摘    要:为了获得90K的低温,提出1套带预冷循环的林德制冷系统,并分别对该系统的预冷循环和制冷循环进行了设计.预冷系统和制冷循环的制冷剂分别为R404A 和 R740.无热负荷时,设定低温箱的温度90 K,制冷量为140 W.该系统整体结构简单,获取温度低,在低温领域有较广泛的应用.

关 键 词:预冷循环  制冷循环  林德制冷机  系统设计
文章编号:1000-6516(2008)01-0038-03
收稿时间:2007-11-23
修稿时间:2007-12-20

System design by using Linder refrigerator with pre-cooling cycle at 90 K
Tang Changzheng,Shi Yang,Wang Shengruan.System design by using Linder refrigerator with pre-cooling cycle at 90 K[J].Cryogenics,2008(1):38-40.
Authors:Tang Changzheng  Shi Yang  Wang Shengruan
Abstract:To obtain the low temperature of 90 K, the Linder refrigeration cycle with pre-cooling cycle was set up. The pre-cooling cycle and refrigeration cycle of the system were designed. The refrigerants of pre-cooling cycle and refrigeration cycle were R404A and R740. The lowest temperature without heat loads was 90 K and the cooling capacity was 140 W. The system has simple structure and gets low temperature, which could be used widely in cryogenic regions.
Keywords:pre-cooling cycle  refrigerantion cycle  Linder refrigerator  system design