首页 | 本学科首页   官方微博 | 高级检索  
     

直埋光缆接头盒进水的原因和解决方法
引用本文:程平辉.直埋光缆接头盒进水的原因和解决方法[J].光纤与电缆及其应用技术,2004(6):39-41.
作者姓名:程平辉
作者单位:中国人民解放军61256部队,维修中心,重庆,400035
摘    要:接头盒进水是直埋光缆的常见故障。根据实际光缆线路整修中发现的问题。简要地探讨了诱发直埋光缆接头盒进水的成因和危害;并依据整修中所获得经验。提出了相应的处理措施。

关 键 词:光缆接头盒  光缆翘曲  阻水纱带
文章编号:1006-1908(2004)06-0039-03

The Causes and Solutions of Water-Ingression into Closures for Buried Fiber Optic Cable
CHENG Ping-hui.The Causes and Solutions of Water-Ingression into Closures for Buried Fiber Optic Cable[J].Optical Fiber & Electric Cable and Their Applications,2004(6):39-41.
Authors:CHENG Ping-hui
Abstract:The water ingression into closures is a common fault in the case of buried fiber optic cable links. Based on the problems found in the renovation of practical fiber optic links the causes and harmfulness of water ingression into closures for buried fiber optic cables are briefly discussed. In addition, on the basis of the experiences obtained during the renovation some dealing measures are recommended.
Keywords:closure  fiber optic cable warp  water-blocking tape