首页 | 本学科首页   官方微博 | 高级检索  
     

670 MW机组汽泵最小流量阀改造
引用本文:燕洪明. 670 MW机组汽泵最小流量阀改造[J]. 东北电力技术, 2014, 35(8): 20-21
作者姓名:燕洪明
作者单位:华电潍坊发电有限公司,山东 潍坊,261204
摘    要:华电潍坊发电有限公司2台670 MW机组汽泵配备的最小流量阀为美国生产的C-V阀,运行过程中阀芯、阀座经常出现冲蚀,造成密封不严,严重影响机组的经济性、安全性。通过测试分析,找出问题根源,对管路、阀芯组件等进行改造使问题得以解决,有效提高了机组运行的安全性及经济性。

关 键 词:最小流量阀  阀芯  管路  改造

Retofitting on Steam Pump Minimum Flow Valve for 670 MW Unit
YAN Hong-ming. Retofitting on Steam Pump Minimum Flow Valve for 670 MW Unit[J]. Northeast Electric Power Technology, 2014, 35(8): 20-21
Authors:YAN Hong-ming
Affiliation:YAN Hong-ming ( Huadian Weifang Power Generation Co. , Ltd. , Weifang, Shandong 261204, China)
Abstract:Turbine-driven feed pump of 670 MW unit turbin used in Weifang Power Generation Co. , Ltd is centrifugal pump of FK4E39 -SC single-stage double-suction centrifugal pump designed by Shanghai Power Plant group. The minimum flow valve is CV valves made in the US. During the operation of valve and valve seat erosion often caused bad sealing, severely affected the economic and safety. Testing analysis is made to identify the root causes of pipeline and valve components to solve the problems, to effectively improve the safety of plant operation, economic performance.
Keywords:Minimum flow valve  Valve  Pipeline  Retrofit