首页 | 本学科首页   官方微博 | 高级检索  
     


Development of two color laser diagnostics for the ITER poloidal polarimeter
Authors:Kawahata K  Akiyama T  Tanaka K  Nakayama K  Okajima S
Affiliation:National Institute for Fusion Science, 322-6 Oroshi-cho, Toki 509-529, Japan. kawahata@lhd.nifs.ac.jp
Abstract:Two color laser diagnostics using terahertz laser sources are under development for a high performance operation of the Large Helical Device and for future fusion devices such as ITER. So far, we have achieved high power laser oscillation lines simultaneously oscillating at 57.2 and 47.7?μm by using a twin optically pumped CH(3)OD laser, and confirmed the original function, compensation of mechanical vibration, of the two color laser interferometer. In this article, application of the two color laser diagnostics to the ITER poloidal polarimeter and recent hardware developments will be described.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏