首页 | 本学科首页   官方微博 | 高级检索  
     


Two color multichannel heterodyne interferometer set up for high spatial resolution electron density profile measurements in TJ-II
Authors:Pedreira P  Esteban L  Criado A R  Acedo P  Sánchez M  Sánchez J
Affiliation:Department of Electronics Technology, Universidad Carlos III de Madrid, Leganes, Madrid 28911, Spain. ppedreir@ing.uc3m.es
Abstract:A high spatial resolution two color [CO(2), λ=10.6?μm/Nd:YAG (Nd:YAG denotes neodymium-doped yttrium aluminum garnet), and λ=1.064?μm] expanded-beam multichannel heterodyne interferometer has been installed on the TJ-II stellarator. Careful design of the optical system has allowed complete control on the evolution of both Gaussian beams along the interferometer, as well as the evaluation and optimization of the spatial resolution to be expected in the measurements. Five CO(2) (measurement) channels and three Nd:YAG (vibration compensation) channels have been used to illuminate the plasma with a probe beam of 100 mm size. An optimum interpolation method has been applied to recover both interferometric phasefronts prior to mechanical vibration subtraction. The first results of the installed diagnostic are presented in this paper.
Keywords:
本文献已被 PubMed 等数据库收录!