首页 | 本学科首页   官方微博 | 高级检索  
     


Marginal discrepancy of all-ceramic crowns cemented on implant abutments
Authors:JK Sutherland  RW Loney  S Syed
Affiliation:Department of Restorative and Prosthetic Dentistry, College of Dentistry, University of Saskatchewan, Saskatoon, Canada.
Abstract:PURPOSE: The purpose of this investigation was to determine the mean marginal discrepancy of all-ceramic crowns cemented on implant abutments. MATERIALS AND METHODS: Five Br?nemark CeraOne abutments were connected to implant fixtures embedded in acrylic resin blocks. The marginal discrepancy was measured using a video camera connected to a digitizing board at four locations on each abutment for five samples in each of the following groups: all-ceramic caps (caps), all-ceramic crowns (crowns), and all-ceramic crowns cemented with zinc phosphate cement (cemented crowns). RESULTS: The mean marginal discrepancies were as follows: caps, 99.0 micrometers (SD, 16); crowns, 117.8 micrometers (SD, 20); and cemented crowns, 168.8 micrometers (SD, 23). Statistically significant differences were found between all three groups at the 99% level of confidence. In addition there were two significant differences between abutments. CONCLUSIONS: Subgingival marginal discrepancies of the magnitude measured in this study have been shown to cause periodontal problems. It is probable that the marginal discrepancy of CeraOne restorations, as tested, can be improved. Efforts should be made to enhance the marginal accuracy of these restorations.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏