An automatic liquid nitrogen filling system |
| |
Authors: | C.P. Monaghan,E.J. O Brien Jr,M.L. Good |
| |
Affiliation: | 1. Division of Engineering Research, Louisiana State University, Baton Rouge, Louisiana 70803, USA;2. Department of Chemistry and Physics, Northwestern State University of Louisiana, Natchitoches, Louisiana 71457, USA |
| |
Abstract: | Spectroscopic measurements at low temperature require liquid nitrogen in some type of research dewar. Often the research dewar must be refilled from a reservoir dewar several times during the course of an experiment. A system is described which automatically refills a research dewar from a reservoir dewar. Two sensors are used for detecting the liquid nitrogen level in the research dewar, and an external nitrogen gas supply is used to provide the pressure to effect the transfer of liquid nitrogen. |
| |
Keywords: | |
本文献已被 ScienceDirect 等数据库收录! |
|