KDN-1000/200Y型高纯氮设备分子筛泄漏故障分析
引用本文:叶楠.KDN-1000/200Y型高纯氮设备分子筛泄漏故障分析[J].深冷技术,2010(2):59-61.
作者姓名:叶楠
作者单位:开封黄河空分集团有限公司,河南省开封市开发区宋城路西段4号475000
摘    要:简介KDN-1000/200Y型高纯氮设备的工艺流程,详细分析因用气量波动大造成分子筛吸附器空气出口过滤器破损,分子筛泄漏进而造成主换热器被分子筛堵塞的故障。介绍为保证供气而对分子筛吸附器所作的临时措施以及最终处理措施。

关 键 词:高纯氮设备  分子筛吸附器  过滤网  泄漏

Analysis of leakage of molecular sieve of Model KDN-1000/200Y high-purity nitrogen equipment
Ye Nan.Analysis of leakage of molecular sieve of Model KDN-1000/200Y high-purity nitrogen equipment[J].Cryogenic Technology,2010(2):59-61.
Authors:Ye Nan
Affiliation:Ye Nan(Kaifeng Huanghe Air Separation Plant Group Co.,Ltd.,4 Western section,Songcheng Road,Development Zone,Kaifeng 475000,Henan,P.R.China)
Abstract:The process of MODEL KDN-1000/200Y high-purity nitrogen equipment is briefed,and the fault of blocking of the main heat exchanger by molecular sieve resulted from damage of air filter outlet of molecular sieve adsorber due to great fluctuation of gas consumption is analyzed in details.The temporary and the final countermeasures taken to molecular sieve adsorber for ensuring normal gas supply are described.
Keywords:High-purity nitrogen equipment  Molecular sieve adsorber  Filtering screen  Leakage  