首页 | 本学科首页   官方微博 | 高级检索  
     


Fatigue Failure of Flanged Thermowell
Authors:Ahmad Ivan Karayan  Yudha Pratesa  Ahmad Ashari  Deni Ferdian
Affiliation:(1) Metallurgy and Materials Engineering, University of Indonesia, Kampus Baru UI Depok, Jawa Barat, 16424, Indonesia
Abstract:A fractured flanged thermowell was received for analysis. The fracture was located at the root of “U” insertion/immersion length which was welded to the flange. The failure of flanged thermowell was attributed to the vortex-induced fatigue. The failure was initiated by the weld failure to withstand the fluctuating load resulted from vortex after years of service. This weld failure then created stress raisers, as evidenced by the ratchet marks and river marks near the outer surface.
Keywords:
本文献已被 SpringerLink 等数据库收录!