首页 | 本学科首页   官方微博 | 高级检索  
     


Experimental investigation of PEM fuel cells for a m-CHP system with membrane reformer
Authors:S. Foresti  G. Manzolini  S. Escribano
Affiliation:1. Politecnico di Milano, Dipartimento di Energia, Via Lambruschini 4, 20156, Milano, Italy;2. CEA/LITEN/DEHT, 17 Rue des Martyrs, 38054, Grenoble Cedex 9, France;3. Univ. Grenoble Alpes, F-38000, Grenoble, France
Abstract:An innovative small-scale cogeneration system based on membrane reformer and PEM fuel cells is under development within the FluidCELL project. An experimental campaign has been carried out to characterize the PEM fuel cell and to define the operative conditions when integrated within the system. The hydrogen feeding the PEM is produced by a membrane reactor which in principle can separate pure hydrogen; however, in general, hydrogen purity is around 99.9%–99.99%. The focus of this work is the assessment of the PEM performance under different hydrogen purities featuring actual membrane selectivity and gases build-up by anode off-gas recirculation. Their effects on the cells voltage and local current distribution are measured at different conditions (pressure, humidity, stoichiometry, with and without air bleeding, in flow-through and dead-end operation). In flow-through mode, the cell voltage is relatively insensitive to the presence of inert gases (e.g. ?20 mV with inerts/H2 from 0 to 20·10?2 at 0.3 A/cm2), and resistant also to CO (e.g. ?35 mV with inerts/H2 = 20·10?2 and CO/H2 from 0 to 20·10?6 at 0.3 A/cm2), thanks to the Ru presence in the anode catalyst. Looking at the current density distribution on the cell surface, the most critical areas are the cathode inlet, likely due to insufficient air humidification, and the anode outlet, because of low hydrogen concentration and CO poisoning of the catalyst. Dead-end operation is also investigated using humid or impure hydrogen. In this case relatively small amount of impurities in the hydrogen feed rapidly reduces the cell voltage, requiring frequent purges (e.g. every 30 s with inerts/H2 = 0.5·10?2 at 0.3 A/cm2). These experiments set the basis for the management of the PEMFC stack integrated into the m-CHP system based on the FluidCELL concept.
Keywords:Micro-cogeneration  Polymeric electrolyte membrane fuel cell  Hydrogen dilution  CO poisoning  Current density distribution
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号