首页 | 本学科首页   官方微博 | 高级检索  
     

上海某节能办公楼暖通空调节能设计
引用本文:鲁迪.上海某节能办公楼暖通空调节能设计[J].制冷空调与电力机械,2010,31(3):45-47,35.
作者姓名:鲁迪
作者单位:广东国得科技发展有限公司,广东,广州,510620
摘    要:介绍了该节能办公楼暖通空调的节能设计:冷热源采用地源热泵,空调系统采用带全热交换器新风机组加无级调速无刷直流风机盘管系统及地板送风变风量空调系统;对比分析了采用这些系统对节能减排的意义。

关 键 词:节能减排  地源热泵  带全热交换器新风机组  无级调速无刷直流风机盘管  地板送风

HVAC Energy-saving Design of a Energy Conservation Office Building in Shanghai
LU Di.HVAC Energy-saving Design of a Energy Conservation Office Building in Shanghai[J].Refrigeration Air Conditioning & Electric Power Machinery,2010,31(3):45-47,35.
Authors:LU Di
Affiliation:LU Di ( Guangdong Gold Science & Technology Development Co., Ltd, Guangzhou 510620, China)
Abstract:In the HVAC energy-saving design,cooling and heating source adopted ground- source heat pump. HVAC system adopted AHU with air-to-air energy exchanger,brushless DC motor fan coil unit and underfloor air distribution system. Then by comparing, its significance for energy conservation & emission reduction was analysed.
Keywords:energy conservation & emission reduction  ground- source heat pump  AHU with air-to-air energy exchanger  brushless DC motor fan coil unit  underfloor air distribution system
本文献已被 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号