首页 | 本学科首页   官方微博 | 高级检索  
     

洞巴水电站大坝混凝土面板裂缝问题的处理
引用本文:龙晗. 洞巴水电站大坝混凝土面板裂缝问题的处理[J]. 红水河, 2009, 28(4): 103-105
作者姓名:龙晗
作者单位:广西百色电力有限责任公司,广西,百色,533000
摘    要:通过对洞巴水电站面板堆石坝混凝土裂缝的原因进行详细分析,确定采用SR止水材料的处理措施.经过实践检验,面板裂缝处理效果良好,满足裂缝封闭和防止渗水的要求.

关 键 词:混凝土面板  裂缝  原因分析  处理措施  SR止水材料  洞巴水电站

Treatment against Concrete Slab Fissure on Dam of Dongba Hydropower Station
LONG Han. Treatment against Concrete Slab Fissure on Dam of Dongba Hydropower Station[J]. Hongshui River, 2009, 28(4): 103-105
Authors:LONG Han
Affiliation:Guangxi Baise Electric Power Co.;Ltd;Baise 533000
Abstract:The cause of concrete fissure on face rock fill dam of Dongba Hydropower Station is studied,and it is determined to use SR sealing material to solve the problem.As a result,the fissure is treated well for such material is able to handle the fissure and prevent seepage.
Keywords:concrete slab  fissure  cause analysis  countermeasure  SR sealing material  Dongba Hydropower Station  
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号