摘    要:提出以双氧水作为氧化剂去除硫酸污水中砷的方法,并对此方法进行可行性试验的研究。在工业试验中,石灰乳中和预处理工段处理后水中砷含量能由原来的11.80mg/L的平均值降到2.34mg/L,膜过滤器深度处理工段处理后水中含砷量能由原来的0.82mg/L的平均值降到0.13mg/L。

关 键 词:双氧水  除砷  硫污酸水

Experimental Study of Removal of Arsenic in Sulfuric Acid Wastewater with Hydrogen Peroxide
Affiliation:TANG fian, CHEN Xue - xing, LI Gui - yun (Hunan Shuikoushan Nonferrous Metals Group Co. , Ltd. , Hunan Changning 421513, China)
Abstract:i The approach of removing arsenic in the sulfuric acid wastewater with hydrogen peroxide as an oxidant was proposed, which was to conduct a feasibility study experiments. In industrial trials, milk of lime and pre - treated water arsenic section can be increased from 11.80 mg/L, average dropped to 2.34 mg/L, membrane filter depth treatment section arsenic treated water can be increased from the 0. 82 mg/L, and the average was reduced to 0. 13 mg/L.