High temperature EMAT design for scanning or fixed point operation on magnetite coated steel |
| |
Affiliation: | 1. Department of Physics, University of Warwick, Coventry CV4 7AL, United Kingdom;2. Sonemat Ltd., 34 High Street, Walsall, West Midlands WS9 8LZ, United Kingdom |
| |
Abstract: | Bulk thickness measurements were performed at elevated temperatures on magnetite coated low carbon steel pipe and aluminium samples, using a permanent magnet electromagnetic acoustic transducer (EMAT). The design presented here exploits the non-contact nature of EMATs to allow continuous operation at elevated temperatures without physical coupling, sample preparation (in the form of oxide scale removal), or active cooling of the EMAT. A non-linear change in signal amplitude was recorded as the magnetite coated sample was heated in a furnace, whereas a steady decrease in amplitude was observed in aluminium. For a magnetite coated pipe sample, after a dwell time of 3 h, a SNR of 33.4 dB was measured at 450 °C, whilst a SNR of 33.0 dB was found at 25 °C. No significant EMAT performance loss was observed after one month of continuous exposure to 450 °C. EMAT-sample lift-off performance was investigated at elevated temperature on magnetite coated steel; a single-shot SNR of 31 dB for 3.0 mm lift-off was recorded at 450 °C, highlighting the suitability of this design for scanning or continuous fixed point inspection at high temperature. |
| |
Keywords: | EMAT High temperature Thickness measurement Magnetostriction |
本文献已被 ScienceDirect 等数据库收录! |
|