摘    要:通过对某电厂高压电机轴承过热故障进行分析,阐述了变频调速电动机轴电压和轴电流产生的原因,形成的危害以及采取的技术措施。

关 键 词:变频调速  轴电流  轴承  绝缘

Fault Analysis on the Burned Motor Bearing Caused by Bearing Current
Zhou Wen,Tang Jianhui,Kang Lihua.Fault Analysis on the Burned Motor Bearing Caused by Bearing Current[J].Explosion-proof Electric Machine,2010,45(1):34-35,42.
Authors:Zhou Wen  Tang Jianhui  Kang Lihua
Affiliation:Zhou Wen, Tang Jianhui, and Kang Lihua
Abstract:Through analyzing failure of the overheated high-voltage motor bearing in a electric station,this paper describes the reasons and harms produced by shaft voltage and shaft current of the variable-frequency adjustable-speed motor as well as the technical measures that should be taken.