首页 | 本学科首页   官方微博 | 高级检索  
     


EVALUATION OF THE DYNAMIC PERFORMANCE OF A HOT WATER TANK WITH BUILT-IN HEATING COIL
Authors:Libing Yang  Benny Bhm  Otto Paulsen  Svend Frederiksen
Abstract:Hot water tanks with a built-in water-heating coil are commonly used in district heating house stations in Denmark for domestic hot water (DHW) production and storage. In this study, an evaluation of the dynamic performance of a hot water tank with built-in heating coil is carried out by applying a dynamic simulation programme which has been made previously, based on a simple dynamic model developed by the authors. System evaluation of the way in which system parameters, such as control valve size, heat loss coefficient of the DHW circulation pipe, position of the temperature sensor (for DHW temperature control) and fouling of the heating coil, affect the domestic hot water capacity and the average district heating water cooling for a given hot water tank is presented and discussed in this paper. The evaluation results show the importance of the correct design of the control valve size, the reduction of heat loss from DHW circulation pipes, the careful adjustment of temperature sensor position and temperature sensor set-point, and the reduction of the heat coil fouling growth rate in order to operate the hot water tank in an efficient way and to achieve significant cooling of the district heating water. © 1997 by John Wiley & Sons, Ltd.
Keywords:hot water storage  domestic hot water  dynamic performance