摘    要:分析长沙地区10 kV配电网现有的中性点经消弧线圈接地方式及现有的接地方式存在的弊端,提出改造方案:在长沙重负荷的城区将消弧线圈接地方式改造为中性点经小电阻接地方式,在城乡结合部仍保留现有的中性点经消弧线圈接地方式.

关 键 词:10kV配电网  接地方式  消弧线圈  小电阻接地方式

Status and conversion of neutral grounding model in distribution network in Changsha
Authors:ZHOU Yong-ming  PENG Dong-fei  LIU Ke
Affiliation:ZHOU Yong-ming1,PENG Dong-fei2,LIU Ke3
Abstract:This paper analyzed the neural grounding system with perterson coil in 10 kV distribution network in Changsha.The shortcomings of existing neural grounding system are analyzed,and the retrofitting scheme of the grounded system for 10 kV distribution networks in Changsha is proposed.The heavy loaded substations near to load center are to be retrofitted to ground with small resistance,and the suburb substation will be reserved unchanged.
Keywords:10 kV distribution network  grounded model  arc suppression coil  grounding via resistance