首页 | 本学科首页   官方微博 | 高级检索  
     


Ammonia removal by air stripping in a semi-batch jet loop reactor
Authors:Nejdet De?ermenci  Osman Nuri Ata  Ergun Yild?z
Affiliation:1. Environmental Engineering Department, Engineering Faculty, Ataturk University, 25240 Erzurum, Turkey;2. Chemical Engineering Department, Engineering Faculty, Atatürk University, 25240 Erzurum, Turkey
Abstract:Ammonia is very toxic chemical and it can be removed by air stripping at high pH. JLRs have found applications in wastewater treatment processes due to their high mass transfer rates. In JLRs, intrinsic high turbulence result in a very large air-liquid surface area for greater mass transfer. Therefore, in this study, ammonia removal by air stripping from synthetically prepared ammonia solution at the high pH in a semi-batch JLR due to its high mass transfer capabilities have been investigated. Investigated parameters in a JLR were initial ammonia concentration (10–500 mg/L), temperature (20–50 °C), air flow rate (5–50 L/min) and liquid circulation rate (35–50 L/min). While it was demonstrated that temperature and air flow rate have a significant effect on the ammonia removal, it was determined that initial ammonia concentration and liquid circulation rate have no significant effect on the ammonia removal. The overall volumetric mass transfer coefficients (KLa) have been calculated from obtained model and it was determined that increasing temperature and air flow rate have a very significant effect on KLa. It was concluded that JLR provides higher mass transfer capabilities than other type of reactors even if less air is given.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号