首页 | 本学科首页   官方微博 | 高级检索  
     

电站锅炉屏式过热器爆管原因分析
引用本文:刘励,徐贤,吴国忠,夏福庆. 电站锅炉屏式过热器爆管原因分析[J]. 宁夏电力, 2006, 0(2): 41-44
作者姓名:刘励  徐贤  吴国忠  夏福庆
作者单位:1. 宁夏电力科技教育工程院,银川市,750002
2. 宁夏大坝发电有限责任公司,青铜峡市,7516007
摘    要:针对大坝发电厂#2锅炉屏式过热器爆管问题进行研究分析,找出爆管的直接原因是由于焊缝质量问题,导致管子严重堵塞,蒸汽流通不畅,管子长期过热引起,提出了相应的防范措施,以保证锅炉运行的安全性和可靠性。

关 键 词:屏式过热器  焊缝  过热  爆管
文章编号:1672-3643(2006)02-0041-03
修稿时间:2005-12-15

Cause analysis of the platen superheater blast at power station
LIU Li,XU Xian,WU Guo-zhong,XIA Fu-qing. Cause analysis of the platen superheater blast at power station[J]. Ningxia Electric Power, 2006, 0(2): 41-44
Authors:LIU Li  XU Xian  WU Guo-zhong  XIA Fu-qing
Abstract:Analyzes the cause of platen superheater blast at No. 2 boiler in Daba Power Plant, points out the direct reason of blast is the pipes welding seam quality, caused by the pipes stopped seriously, the steam circulating slack and long-term to overheat, puts forward relevant preventive measures, ensures the safety and the credibility of the boiler operation.
Keywords:platen superheater  welding seam  overheat  pipe blast
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号