首页 | 本学科首页   官方微博 | 高级检索  
     

反渗透系统保安过滤器滤芯污堵原因分析及处理
引用本文:刘向朝,陈玉琨. 反渗透系统保安过滤器滤芯污堵原因分析及处理[J]. 工业水处理, 2016, 0(6): 99-102
作者姓名:刘向朝  陈玉琨
作者单位:1. 中海油天津化工研究设计院有限公司,天津,300131;2. 大唐内蒙古多伦煤化工有限责任公司,内蒙古多伦,010206
摘    要:福建某新材料公司脱盐水系统在运行一段时间后,其反渗透系统保安过滤器滤芯出现污堵,影响了脱盐水系统的正常运行。对污堵原因进行了分析,并提出了相应的改进措施。改进措施实施后,彻底解决了反渗透保安过滤器滤芯的污堵问题,脱盐水产水率得以恢复。

关 键 词:反渗透  保安过滤器滤芯  微生物污染  还原剂

Cause analysis on the pollution and blockage in the security filter core of reverse osmosis system and its treatment
Abstract:After the desalted water system of a new material company in Fujian,China has run for a period of time, pollution and blockage occur to the security filter core of the reverse osmosis system ,affecting the normal operation of the desalted water system. The causes of pollution and blockage are analyzed and corresponding improving measures are put forward. After the improving measures have been implemented,the pollution and blockage problems of reverse osmosis security filter core are solved completely. As a result ,the water yield of desalination water can be restored.
Keywords:reverse osmosis  security filter core  microbial pollution  reducing agent