Abstract:For the optimization of electrical insulation design for high temperature superconducting (HTS) cable, evaluation of electrical insulation characteristics especially for butt gap of LN/sub 2/ impregnated cold dielectric (CD) which consists of the wrapped tape insulation impregnated with LN/sub 2/ plays an important role. This paper presents partial discharge (PD) inception and breakdown characteristics in LN/sub 2/ impregnated butt gap model which modeled a weak point of the wrapped tape insulation impregnated with LN/sub 2/ and cable model with short length with polypropylene laminated paper (PPLP/sup /spl reg//), Nomex/sup /spl reg// paper and cellulose paper. PD current pulse was found to have a steep rise time of /spl sim/ ns and amplitude of /spl sim/ tens /spl mu/A at PD inception voltage region. Little dependency of breakdown stress on the insulating material is found. PD inception stress is almost independent of insulation thickness of 1 to 3 mm. The requirement insulation thickness for 66 kV class HTS cable is estimated to be /spl sim/ 5 mm under PD-free condition from viewpoint of long-term reliability.