首页 | 本学科首页   官方微博 | 高级检索  
     

超压工况主蒸汽阀站先导阀的动态特性研究
引用本文:刘闯,臧家林,姚怀宇,陈时健,朱京梅,金瑞兴,钱锦远. 超压工况主蒸汽阀站先导阀的动态特性研究[J]. 液压与气动, 2022, 0(10): 24-30. DOI: 10.11832/j.issn.1000-4858.2022.10.004
作者姓名:刘闯  臧家林  姚怀宇  陈时健  朱京梅  金瑞兴  钱锦远
作者单位:1.浙江大学化工机械研究所, 浙江杭州 310027; 2.核电运行研究(上海)有限公司, 上海 200120; 3.中核苏阀科技实业股份有限公司, 江苏苏州 215129; 4.中国核电工程公司, 北京 100840; 5.浙江大学流体动力与机电系统国家重点实验室, 浙江杭州 310027
基金项目:国家自然科学基金(52175067);浙江省重点研发计划(2021C01021)
摘    要:为保障核电站安全稳定运行,针对核电站关键超压保护设备主蒸汽阀站,研究了其先导阀在不同超压速度下的动态特性,并分析了在先导阀开启过程中响应时间和阀杆瞬态受力的变化趋势。研究表明,增大超压速度会使VS66和NICO先导阀的响应时间降低;当超压速度达到3 MPa/s时,NICO和VS66阀杆的最大受力值均大于其超压速度在0, 1, 2 MPa/s时的最大受力值。

关 键 词:主蒸汽阀站  超压速度  流体力  响应时间
收稿时间:2021-12-22

Dynamic Characteristics Analysis on Pilot Valve of Main Steam Valve Set Under Overpressure Working Condition
LIU Chuang,ZANG Jia-lin,YAO Huai-yu,CHEN Shi-jian,ZHU Jing-mei,JIN Rui-xing,QIAN Jin-yuan. Dynamic Characteristics Analysis on Pilot Valve of Main Steam Valve Set Under Overpressure Working Condition[J]. Chinese Hydraulics & Pneumatics, 2022, 0(10): 24-30. DOI: 10.11832/j.issn.1000-4858.2022.10.004
Authors:LIU Chuang  ZANG Jia-lin  YAO Huai-yu  CHEN Shi-jian  ZHU Jing-mei  JIN Rui-xing  QIAN Jin-yuan
Affiliation:1. Institute of Process Equipment, Zhejiang University, Hangzhou, Zhejiang310027; 2. Nuclear Power Operations Research Institute, Shanghai200120; 3. SUFA Technology Industry Co., Ltd., Suzhou, Jiangsu215129; 4. China Nuclear Power Engineering Co., Ltd., Beijing100840; 5. State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou, Zhejiang310027
Abstract:In order to ensure the reliable and stable operation of the nuclear power plant, this paper investigates the dynamic characteristics of the pilot valve on the main steam valve set at different over pressure speeds, which is the critical over pressure protection equipment in nuclear power plant, and analyzes the response time and the transient force of valve stem during the opening process of the pilot valve. The results show that increasing over pressure speed can reduce the response time of the VS66 and NICO pilot valves. When the over pressure speed reach 3 MPa/s, the maximum forces of VS66 and NICO pilot valve are both greater than those at 0, 1 and 2 MPa/s.
Keywords:main steam valve set  overpressure speeds  fluid force  response time  
点击此处可从《液压与气动》浏览原始摘要信息