首页 | 本学科首页   官方微博 | 高级检索  
     

用残差CUSUM控制图检测自相关过程中的故障
引用本文:王海涛,陈友明,陈永康等.用残差CUSUM控制图检测自相关过程中的故障[J].振动.测试与诊断,2012,32(1):73-77.
作者姓名:王海涛  陈友明  陈永康等
作者单位:1. 湖南大学土木工程学院长沙,410082;河南工业大学土木建筑学院郑州,450000
2. 湖南大学土木工程学院长沙,410082
3. 香港太古地产有限公司技术统筹部 中国香港
基金项目:香港太古地产建筑智能控制研究基金资助项目(编号:JRP0901);湖南省科技计划重点资助项目(编号:2010WK4018)
摘    要:由于累积和控制图(cumulative sum,简称CUSUM)算法应用的基本假设是从过程得到的观测值彼此独立,而工业过程通常是自相关过程,数据自相关性会影响CUSUM控制图的性能.针对这一问题,利用数学推理的方法分析了数据自相关性对CUSUM控制图性能的不利影响,正自相关会使CUSUM控制图的平均运行长度变短,可能引起假警报;负自相关会使CUSUM控制图的平均运行长度变长,可能造成故障漏报.在此基础上,提出用残差CUSUM控制图来检测自相关过程中的故障,运用时间序列模型的残差检测自相关过程中的故障,消除数据自相关性对控制图性能的不利影响.结果表明,该方法具有较好的鲁棒性和较高的准确率.

关 键 词:自相关过程  一阶自回归模型  残差  累积和控制图  故障检测

Application of Residual-Based Cumulative Sum Control Charts for Detecting Faults in Autocorrelated Processes
Wang Haitao,Chen Youming,Cary W H Chan,Qin Jianying.Application of Residual-Based Cumulative Sum Control Charts for Detecting Faults in Autocorrelated Processes[J].Journal of Vibration,Measurement & Diagnosis,2012,32(1):73-77.
Authors:Wang Haitao  Chen Youming  Cary W H Chan  Qin Jianying
Affiliation:1.College of Civil Engineering,Hunan University Changsha,410082,China) (2.School of Civil Engineering and Architecture,Henan University of Technology Zhengzhou,450000,China) (3.Technical Services Department,Swire Properties LTD Hong Kong,China)
Abstract:Cumulative sum(CUSUM) control charts are constructed under the assumption that the observations taken from the process of interest are independent over time.However,the observations in many industrial cases are actually correlated.Serial correlation of observations will result in poor performance of control charts.The effect of serial correlation on the performance of control charts is analyzed through mathematical analysis method.Positive serial correlation decreases the average run length(ARL) of CUSUM control chart,resulting in too many false alarms.Negative serial correlation increases the ARL of CUSUM control chart,which possibly results in missing faults.In addition,a fault detection method for autocorrelated processes is presented by using residual-based CUSUM control chart.The residuals between the process error and its predication are generated using autoregressive time-series models.Then,CUSUM control charts are used to monitor the residuals which are statistically independent.The residual-based CUSUM control chart can improve the accuracy of fault detection through eliminating the effects of serial correlation on the performance of control charts.Some case studies show that the residual-based CUSUM control chart is an effective tool in detecting faults of autocorrelated processes,and the fault detection method has good robustness and high accuracy rate.
Keywords:autocorrelated process  first order autoregressive model  residual  cumulative sum control chart  fault detection
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《振动.测试与诊断》浏览原始摘要信息
点击此处可从《振动.测试与诊断》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏