摘    要:介绍ZF4A-126型气体绝缘金属封闭开关设备的结构、工作原理、技术参数;总结和介绍110kVSF6封闭式组合电器的检修步骤,检修设备所涉及的SF6气体处理、工艺要求等注意事项及人身安全防护,并提出合理化建议。

关 键 词:SF6封闭式组合电器(GIS)  SF6气体绝缘  设备检修步骤

Maintenance of 110kV SF6 Gas-insulated Switchgear
LU Wei-hong.Maintenance of 110kV SF6 Gas-insulated Switchgear[J].Journal of Jiangxi Electrical University For Staff,2009(4):37-39.
Authors:LU Wei-hong
Affiliation:LU Wei-hong (Shenzhen Power Supply Bureau, Guangdong Shenzhen 518020,China)
Abstract:The ZF4A-126-type gas-insulated metal-enclosed switchgear's structure, working principle, technical parameters are introduced; 1 lOkV SF6 enclosed switchgear's maintenance steps involved in maintenance of equipment to deal with SF6 gas, process requirements notes and personal safety protection are summarized and introduced, and Some suggestions are proposed.
Keywords:Gas-Insulated Switchgear  gas-insulated  maintenance steps