首页 | 本学科首页   官方微博 | 高级检索  
     

ICP-OES法测定密蒙花中多种元素
引用本文:聂西度,符靓. ICP-OES法测定密蒙花中多种元素[J]. 食品科学, 2014, 35(18): 93-95. DOI: 10.7506/spkx1002-6630-201418018
作者姓名:聂西度  符靓
作者单位:1.湖南工学院材料与化学工程学院,湖南 衡阳 421002;2.长江师范学院化学化工学院,重庆 408100
基金项目:国家自然科学基金面上项目(21075138);重庆市教委科学技术研究重点项目(KJ1401209);湖南省科技计划项目(2013FJ3093);湖南省教育厅重点科研项目(14A035);湖南省重点学科建设项目(湘教发[2011]76号)
摘    要:建立电感耦合等离子体发射光谱法测定密蒙花中Na、Mg、P、K、Ca、Mn、Fe、Cu、Zn、Sr人体必需元素和Ni、As、Cd、Pb毒理性元素的分析方法。样品经(硝酸+双氧水)密闭微波消解后用超纯水稀释后进行测定,确定各待测元素的分析波长,通过加入内标元素Y补偿待测元素分析信号的漂移,校正基体效应,改善分析信号的稳定性。在选定的操作条件下,各待测元素的检出限在0.011~25.16 μg/L之间,利用标准参考物质(NIST SRM 1515)验证分析方法的准确度和精密度,结果表明,标准物质的分析结果与参考值基本一致,相对标准偏差为2.0%~8.3%。方法简便、快速、准确,能实现密蒙花中多元素的快速分析。

关 键 词:电感耦合等离子体发射光谱法  密蒙花  必需元素  毒理性元素  

Determination of Multiple Elements in Flos Buddlejae by Inductively Coupled Plasma Optical Emission Spectrometry
NIE Xi-du,FU Liang. Determination of Multiple Elements in Flos Buddlejae by Inductively Coupled Plasma Optical Emission Spectrometry[J]. Food Science, 2014, 35(18): 93-95. DOI: 10.7506/spkx1002-6630-201418018
Authors:NIE Xi-du  FU Liang
Affiliation:1. College of Material and Chemical Engineering, Hunan Institute of Technology, Hengyang 421002, China;2. College of Chemistry and Chemical Engineering, Yangtze Normal University, Chongqing 408100, China
Abstract:A new method for the determination of essential elements (Na, Mg, P, K, Ca, Mn, Fe, Cu, Zn, and Sr) and toxic
elements (Ni, As, Cd, and Pb) in Flos Buddlejae was established using inductively coupled plasma optical emission spectrometry
(ICP-OES). Nitric acid and hydrogen peroxide were used jointly to achieve the complete decomposition of the organic matrix in a
closed-vessel microwave oven. Appropriate analysis lines for various elements were selected. Y as internal standard element was
used to compensate matrix effect and signal drift, and the stability of the instrument was improved. Under the optimal conditions,
the detection limits were 0.011–25.16 μg/L. The accuracy and precision of this method were confirmed through reference standard
materials (NIST SRM 1515, apple leaves). The results showed a good agreement between measured and predicted values for all
analyzed elements. The relative standard deviation (RSD) was in the range of 2.0% to 8.3%. This method proved simple, sensitive
and precise and could allow simultaneous multi-element determination of Flos Buddlejae.
Keywords:inductively coupled plasma optical emission spectrometry  Flos Buddlejae  essential elements  toxic elements  
本文献已被 CNKI 等数据库收录!
点击此处可从《食品科学》浏览原始摘要信息
点击此处可从《食品科学》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号