摘    要:本文介绍了国产单色仪快速组织自动光谱辐射计的方法及其方法。应用该系统可测量光源或辐射源的光谱辐射特性,进而得到当代评价光源的重要技术参数;三刺激值,色温,相关色温,显色指数等。

关 键 词:光谱辐射计  单色仪  三刺激值  色温  显色指数

Quickly Setting Automated Spectroradiometer Using Simple Monochrometer
Zhang Jianmin,Liu Qin.Quickly Setting Automated Spectroradiometer Using Simple Monochrometer[J].Modern Scientific Instruments,2000(4):47-48.
Authors:Zhang Jianmin  Liu Qin
Abstract:A method of quickly setting automated spectroradiometer using a simple monochrometer and it's application is described in the article. It is able to measure the spectral radiation characteristic of a light source or radiator by the facility. The important technical parameters to evaluate the light source recently are got sequentially: tristimulus value, color temperature, color-rendering index etc.