首页 | 本学科首页   官方微博 | 高级检索  
     

原子吸收光谱法测定贵金属合金中的铬
引用本文:陈 雯,赵文虎,金娅秋,毛 端,陈国华,赖丽君,刘 莉. 原子吸收光谱法测定贵金属合金中的铬[J]. 贵金属, 2016, 37(2): 65-69. DOI: 10.3969/j.issn.1004-0676.2016.02.013
作者姓名:陈 雯  赵文虎  金娅秋  毛 端  陈国华  赖丽君  刘 莉
作者单位:贵研铂业股份有限公司 稀贵金属综合利用新技术国家重点实验室,昆明,650106
摘    要:采用原子吸收光谱法测定Co Cr Pt Si O2、Au Ni Cr、Ni Pd Cr BSi、Ni Cr B合金中铬含量,研究了影响铬测定的因素及其消除条件。结果表明,用盐酸-硝酸、氢氟酸密闭消解样品,高氯酸发烟驱除剩余氢氟酸,氯化铵或水合肼消除大量镍(II)、硅(IV)或金(III)的影响,用亚硫酸钠转化可将铬(VI)完全转化为高灵敏度的铬(III);标准曲线线性范围0~6.00μg/m L,检出限0.004μg/m L;测定含量为5%~7%的铬,相对标准偏差0.82%~1.29%,加标回收率为93.34%~110.80%。

关 键 词:分析化恘  原子吸收光谱法  贵金属合金  
收稿时间:2015-05-20

Determination of Chromium in Precious Metal-based Alloys by Atomic Absorption Spectrometry
CHEN Wen,ZHAO Wenhu,JIN Yaqiu,MAO Duan,CHEN Guohu,LAI Lijun and LIU Li. Determination of Chromium in Precious Metal-based Alloys by Atomic Absorption Spectrometry[J]. Precious Metals, 2016, 37(2): 65-69. DOI: 10.3969/j.issn.1004-0676.2016.02.013
Authors:CHEN Wen  ZHAO Wenhu  JIN Yaqiu  MAO Duan  CHEN Guohu  LAI Lijun  LIU Li
Affiliation:State Key Laboratory of Advanced Technologies of Comprehensive Utilization of Platinum Metals,Sino-Platinum Metals Co. Ltd., Kunming 650106, China,State Key Laboratory of Advanced Technologies of Comprehensive Utilization of Platinum Metals,Sino-Platinum Metals Co. Ltd., Kunming 650106, China,State Key Laboratory of Advanced Technologies of Comprehensive Utilization of Platinum Metals,Sino-Platinum Metals Co. Ltd., Kunming 650106, China,State Key Laboratory of Advanced Technologies of Comprehensive Utilization of Platinum Metals,Sino-Platinum Metals Co. Ltd., Kunming 650106, China,State Key Laboratory of Advanced Technologies of Comprehensive Utilization of Platinum Metals,Sino-Platinum Metals Co. Ltd., Kunming 650106, China,State Key Laboratory of Advanced Technologies of Comprehensive Utilization of Platinum Metals,Sino-Platinum Metals Co. Ltd., Kunming 650106, China and State Key Laboratory of Advanced Technologies of Comprehensive Utilization of Platinum Metals,Sino-Platinum Metals Co. Ltd., Kunming 650106, China
Abstract:Chromium contents in CoCrPtSiO2, AuNiCr, NiPdCrBSi, NiCrB alloy were determined by using atomic absorption spectrometry, the interference from other elements in the determination was investigated and the eliminating method was given. After the sample is transferred into the aqueous solution with a mixture of hydrochloric acid, nitric acid and hydrofluoric acid, the remaining hydrofluoric acid in the sample is dispelled by using perchloric acid. And then Ni(II) and Si(IV) are removed by precipitation with ammonium chloride, whereas Au(III) is removed by reduction with hydrazine hydrate. The conversion of Cr(VI) into Cr (III) gives rise to a final solution which will be submitted for AAS measurements. The standard working curve is linear in the range of 0~6.00 μg/mL with a detecting limit of 0.004 μg/mL. When chromium content is between 5%to 7%in the samples, the relative standard deviation can be less than 1.29%. The recovery for standard addition ranges from 93.34%to110.80%.
Keywords:analytical chemistry  AAS  precious metals alloys  chromium
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《贵金属》浏览原始摘要信息
点击此处可从《贵金属》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号